Título Tema Apresentador
MAIS
Activity determination of a 201Tl solution by 4pi?-gama and sum-peak coincidence methods Metrologia de radionuclídeos Anelise Ruzzarin
AMBIENT RADIATION LEVELS IN A RESEARCH LABORATORY DUE MICROPET/CT. Metrologia em raios X, raios gama, elétrons e partículas carregadas Janete Cristina G G Carneiro
APLICAÇÃO DE METODOLOGIA TANDEM EM PROCEDIMENTOS DE RADIOPROTEÇÃO Metrologia em raios X, raios gama, elétrons e partículas carregadas maria do socorro nogueira tavares
Application of patent BR102013018500-0 in well type ionization chambers Instrumentação e infraestrutura para laboratórios Carlos Henrique Simões de Sousa
Assessment of radioactivity level in granite stones sold to ornamental and building purposes Metrologia em raios X, raios gama, elétrons e partículas carregadas Yan Maia de Queiroz
Attenuation coefficient determination of printed ABS and PLA in diagnostic radiology standard beams Metrologia em raios X, raios gama, elétrons e partículas carregadas Glauco Rogério Veneziani
Avaliação da dep. energética de câmaras de ionização tipo lápis calibradas em feixes padrões de TC. Metrologia em raios X, raios gama, elétrons e partículas carregadas Ladyjane Pereira Fontes
Avaliação das incertezas no processo de calibração cruzada de câmaras de placas paralelas Metrologia em raios X, raios gama, elétrons e partículas carregadas Ernani Anderson
Avaliação de uma câmara de ionização tipo lápis especial pelo método de Monte Carlo Metrologia e instrumentação em radiações ionizantes Ana Paula Perini
Avaliação do desempenho de dosímetros eletrônicos para monitoração individual: testes em laboratório Metrologia em raios X, raios gama, elétrons e partículas carregadas William Jaramillo Garzón
Calibração de câmaras de ionização do tipo poço Metrologia e instrumentação em radiações ionizantes Carlos Frederico Estrada Alves
Caracterização dos feixes de 60Co e 137Cs do Irradiador Shepherd 81 – 14D Metrologia em raios X, raios gama, elétrons e partículas carregadas Cosme N. Mello da Silva
Caracterização e Implantação de Qualidades de Radiação Padronizadas em um Irradiador de Animais Metrologia em raios X, raios gama, elétrons e partículas carregadas Leslie Pereira
Characterization of a free air ionization chamber for low energies Metrologia em raios X, raios gama, elétrons e partículas carregadas Linda V. E. Caldas
Comparação entre medidas de camada semirredutora: câmara de ionização vs medidores de estado sólido. Metrologia em raios X, raios gama, elétrons e partículas carregadas Lara Catrine Silva Pereira
Comparação entre métodos de calibração do Produto kerma-área Metrologia em raios X, raios gama, elétrons e partículas carregadas Valéria Navarro
Comparison of surface contamination monitors for in vivo measurement of 131-I in thyroid Metrologia nas áreas de saúde, indústria e proteção radiológica Salomão Marques de Oliveira
Conhecendo a potencia de um equipamento de raios x Metrologia em raios X, raios gama, elétrons e partículas carregadas vitor moura de paula
Controle da qualidade do 99mTc Metrologia e instrumentação em radiações ionizantes Mirella carvalho da silva kabad
Controle de qualidade e estabilidade de dosímetros usados em radioterapia empregando fontes de 137Cs Metrologia e instrumentação em radiações ionizantes Carlos Frederico Estrada Alves
Desenvolvimento das Condições de Radiação em Tomografia Computadorizada - TC Metrologia em raios X, raios gama, elétrons e partículas carregadas Ricardo de Souza Cardoso
Desenvolvimento de um relógio digital com arduino utilizando base de tempo rastreável Metrologia em raios X, raios gama, elétrons e partículas carregadas Bruno de Oliveira Jordão
Determinação da taxa de kerma no ar de referência para 192Ir de alta taxa de dose para braquiterapia Metrologia e instrumentação em radiações ionizantes Carlos Frederico Estrada Alves
Determinação da tensão aplicada em um tubo de raios X através do espectro Metrologia em raios X, raios gama, elétrons e partículas carregadas marcos aurélio gomes de albuquerque
Determinação do centro efetivo de um detector Long Counter no Laboratório de Metrologia de Nêutrons. Metrologia em raios X, raios gama, elétrons e partículas carregadas Simone da Silva Fernandes
Determinação do rendimento químico na dosimetria Fricke para fontes de 192Ir usadas em braquiterapia Metrologia em raios X, raios gama, elétrons e partículas carregadas Mariano Gazineu David
Determination of correlated uncertainties of sestamibi- 99mTc marking Metrologia em raios X, raios gama, elétrons e partículas carregadas Carlos Henrique Simões de Sousa
Determination of the 121Te gamma emission probabilities associated to radiopharmaceutical NaI[123I] Metrologia em raios X, raios gama, elétrons e partículas carregadas Miriam Tainá Ferreira de Araújo
DETERMINATION OF THE TRUE NULL ELECTRODE SPACING OF AN EXTRAPOLATION CHAMBER FOR X-RAY DOSIMETRY Metrologia em raios X, raios gama, elétrons e partículas carregadas Marcus Tadeu Tanuri de Figueiredo
Development and evaluation of a technique for in vivo monitoring of 60Co in the lungs Metrologia em raios X, raios gama, elétrons e partículas carregadas jaqueline quince de mello
Estudo das condições de radiação para obtenção do feixe padrão em tomografia computadorizada Metrologia em raios X, raios gama, elétrons e partículas carregadas Lúcio das Chagas de Andrade
Estudo de uma nova matriz vítrea pela técnica de termoluminescência Metrologia em raios X, raios gama, elétrons e partículas carregadas Ana Paula Perini
Exercício de Comparação Laboratorial 2013-2015 Metrologia em raios X, raios gama, elétrons e partículas carregadas Tânia Schirn Cabral
Experimental and Monte Carlo evaluation of an ionization chamber in a 60Co beam Metrologia e instrumentação em radiações ionizantes Ana Paula Perini
Implantação de método não invasivo para calibração de medidores de tensão de pico (kVp) Metrologia em raios X, raios gama, elétrons e partículas carregadas Eric Matos Macedo
Implementação do método pico-soma para padronização de radionuclídeos emissores de pósitrons Metrologia de radionuclídeos Maria da Conceição de Farias Fragoso
Influence of the exposure time in the area monitors at radiodiagnostic Metrologia em raios X, raios gama, elétrons e partículas carregadas Fernando Leyton
Influence of the radioactive source position inside the well-type ionization chamber Metrologia de radionuclídeos lilian toshie kuahara
IRD-CNEN-WBC capabilities for in vivo monitoring of internally deposited radionuclides in human body Metrologia nas áreas de saúde, indústria e proteção radiológica ANA LETÍCIA ALMEIDA DANTAS
Levantamento radiométrico em mamografia: problemas e desafios. Metrologia em raios X, raios gama, elétrons e partículas carregadas Marcus Vinícius Teixeira Navarro
Mammography calibration qualities establishment in a Mo-Mo clinical system Metrologia e instrumentação em radiações ionizantes Eduardo de Lima Correa
MCNP simulation of the incident and albedo neutron response of the IRD albedo neutron dosemeter Metrologia em raios X, raios gama, elétrons e partículas carregadas CLAUDIA LUCIA DE PINHO MAURICIO
Methodology for calibration of ionization chambers for X-ray of low energy in absorbed dose to water Metrologia nas áreas de saúde, indústria e proteção radiológica CAMILA TRINDADE DE OLIVEIRA
Método Alternativo de Irradiação da Solução de MnSO4 por Fonte de PuBe para Medições de Eficiência Metrologia e instrumentação em radiações ionizantes Fellipe Souza da Silva
Método Alternativo de Irradiação da Solução de MnSO4 por Fonte de PuBe para Medições de Eficiência Metrologia e instrumentação em radiações ionizantes Fellipe Souza da Silva
Metrological activity determination of Ba-133 by sum-peak absolute method Metrologia de radionuclídeos Maria Cândida de Almeida
New thermal neutron calibration channel at LNMRI/IRD Metrologia de nêutrons Achilles Astuto
On the response of electronic personal dosimeters in constant potential and pulsed x-ray beams Metrologia em raios X, raios gama, elétrons e partículas carregadas Margarete Cristina Guimarães
OSL response bleaching of BeO samples, using fluorescent light and blue LEDs Metrologia e instrumentação em radiações ionizantes Daniela Piai Groppo
Padronização absoluta do 106Ru pelo método de anticoincidência. Metrologia de radionuclídeos EDUARDA ALEXANDRE REZENDE
Padronização do 57Co por diferentes métodos do LNMRI. Metrologia em raios X, raios gama, elétrons e partículas carregadas EDUARDA ALEXANDRE REZENDE
Performance of the Participant Labs in the Nat. Intercomp Program PNI in the Period from 1991 - 2013 Educação em metrologia, normalização e avaliação da conformidade Maura Julia C. S. Bragança
Performance of three pencil-type ionization chambers (10 cm) in computed tomography standard beams Metrologia em raios X, raios gama, elétrons e partículas carregadas Linda V. E. Caldas
Phantom positioning variation in the Gamma Knife® Perfexion dosimetry Metrologia em raios X, raios gama, elétrons e partículas carregadas NATHALIA ALMEIDA COSTA
Pilot study: relative dose of the TLD, OSL and Radiochromic film applied in CT exams dosimetry Metrologia nas áreas de saúde, indústria e proteção radiológica Kellen Adriana Curci Daros
Portable meter study of ionizing radiation Teletector in high rates of air kerma. Metrologia e instrumentação em radiações ionizantes Willian Behling Damatto
Protocolo técnico da comparação bilateral em Radiologia Diagnóstica: Parte 1 Metrologia em raios X, raios gama, elétrons e partículas carregadas José Guilherme Pereira Peixoto
Protocolo técnico da comparação bilateral em Radiologia Diagnóstica: Parte 2. Metrologia em raios X, raios gama, elétrons e partículas carregadas José Guilherme Pereira Peixoto
Protocolo técnico da comparação bilateral em Radiologia Diagnóstica: Parte 3. Metrologia em raios X, raios gama, elétrons e partículas carregadas José Guilherme Pereira Peixoto
Reference factor "F" _(?"(CT)" ?_"Q" ) and X ray tube ionization yield "R" _(?"(TUBE)" ?_"Q" ) Metrologia em raios X, raios gama, elétrons e partículas carregadas Daniel da Silva Quaresma
Results of an innovative methodology to the dosimetry in mammography examinations Metrologia em raios X, raios gama, elétrons e partículas carregadas João Carlos da Silva Feital
Results of an innovative methodology to the dosimetry in mammography examinations Metrologia em raios X, raios gama, elétrons e partículas carregadas João Carlos da Silva Feital
Simulação de um tubo de raios X clínico através do método de Monte Carlo usando código PENELOPE Metrologia em raios X, raios gama, elétrons e partículas carregadas marcos aurélio gomes de albuquerque
SPECTRA TRANSMITTED BY MORTAR BARITE IN X-RAY QUALITIES APPLIED IN DIAGNOSTIC RADIOLOGY AS SHIELDING Metrologia nas áreas de saúde, indústria e proteção radiológica maria do socorro nogueira tavares
TDCR and CIEMAT/NIST Liquid Scintillation Methods applied to the Radionuclide Metrology Metrologia de radionuclídeos PAULO ALBERTO LIMA DA CRUZ
The influence of different 192Ir sources geometries to the energy deposition Metrologia em raios X, raios gama, elétrons e partículas carregadas Lucio Pereira Neves

Activity determination of a 201Tl solution by 4pi?-gama and sum-peak coincidence methods

Metrologia de radionuclídeos


Resumo

201Tl is used in nuclear medicine in cardiac imaging for evaluating the injury level in cardiac muscle. In this work the activity concentration of a 201Tl radioactive solution has been absolutely determined using the 4pi?-gama coincidence and sum-peak coincidence methods. The presence of 202Tl radioactive impurity that imposes some difficult in the activity measurements was taken into account in the measurements. In the sum-peak method a planar germanium detector was used. The half-lives were evaluated by the reference source method and the results obtained were (3.033 ± 0.004) d and (12.320 ± 0.163) d, respectively, for 201Tl and 202Tl.

Palavras Chave

201Tl; activity; nuclear medicine; coincidence counting; sum-peak counting


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

Monica Aguiar Leobino da Silva, Akira Iwahara, Ronaldo Lins, Octavio Luiz Trindade Filho , R. Poledna, Ricardo Tadeu Lopes

×

AMBIENT RADIATION LEVELS IN A RESEARCH LABORATORY DUE MICROPET/CT.

Metrologia em raios X, raios gama, elétrons e partículas carregadas


Resumo

This study focuses on initial radiological evaluation and the exposure situation related to the worker task in a micro-positron emission tomography/computed tomography laboratory (microPET/CT). Selected and calibrated thermoluminescent dosimeters, TLDs, of CaSO4:Dy were used to measure room radiation levels. The detectors were placed in several selected points inside the microPET/CT laboratory and adjacent rooms. In addition, the occupationally exposed workers were monthly evaluated for external and internal exposures. In none of the selected points the dose values exceeded the radiation dose limit established for supervised area, as well as the values obtained in individual monitoring.

Palavras Chave

THERMOLUMINESCENSE DOSIMETRY; MICROPET/CT; RADIOLOGICAL CONTROL; RADIATION PROTECTION.


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

D M Sarmento, D L Rodrigues, M P SANCHES

×

APLICAÇÃO DE METODOLOGIA TANDEM EM PROCEDIMENTOS DE RADIOPROTEÇÃO

Metrologia em raios X, raios gama, elétrons e partículas carregadas


Resumo

The paper proposes a tandem methodology for measuring average power, tension and CSR in interventional radiology procedures. Isodose curves can be built to suit the dose limits for occupationally exposed individuals. It used two types of TLDs (LiF, LiF-100H and 900) for constructing tandem system on the range 40-150 N - ISO, in narrow spectra. The maximum difference observed for the experimental results was (-8.6%) for the average power and (21.3%) for CSR on 80KV. It has been shown that the use of the tandem system composed of dosimeters of different energy dependence is feasible.

Palavras Chave

tandem system; thermoluminescent dosimeters; interventional radiology


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

Zenóbio, M. A. F., Fernando Leyton, Mello, O., da Silva P. A., Batista Neto, A. T., Almeida Jr, A.T., Renata Ramos da Silveira

×

Application of patent BR102013018500-0 in well type ionization chambers

Instrumentação e infraestrutura para laboratórios


Resumo

The definition of the radioactive sample position in a well type ionization chamber is the largest source of uncertainty in the measurement of quantity activity. The determination of this parameter in two activimeters helped to improve their accuracies, from 2.62 and 2.59% to 3.87 and 1.74%, with and without the use of the positioning device, concluding, that with their use has reached an uncertainty of U = 0.2276 and 0.2677 % (k = 2) 95.45%.

Palavras Chave

ionization chamber; activimeter; uncertainties


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

José Guilherme Pereira Peixoto

×

Assessment of radioactivity level in granite stones sold to ornamental and building purposes

Metrologia em raios X, raios gama, elétrons e partículas carregadas


Resumo

The aim of this work was evaluate the level of radioactivity in granite sold in the region of Belém (Pará, Brazil) using a Geiger-Müller detector. The results showed that only 5 from 57 samples of 35 types of granite evaluated had count rates above that measured in the Background. However, the counting statistics suggests that the measured radiation values in these 5 samples are not due random fluctuations inherent in such measures.

Palavras Chave

granite; radiation; building material; Geiger-Muller.


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

Roberto José Carneiro Santos, Cláudio Eduardo Corrêa Teixeira

×

Attenuation coefficient determination of printed ABS and PLA in diagnostic radiology standard beams

Metrologia em raios X, raios gama, elétrons e partículas carregadas


Resumo

IAEA TRS-457 states standard phantoms should offer the same primary attenuation and scatter production as relevant body section of a representative patient. Material cost, availability and dimensional stability must also be considered. The goal of this study is to determine printed ABS and PLA attenuation coefficient in standard X-ray beams, verifying if phantoms printed with these materials could be an easier-handle substitute for PMMA, enabling the creation of different designs in an easier and cheaper way. Results show that PMMA presents higher attenuation coefficient, followed by PLA and ABS, which means that thinner PMMA layer creates higher radiation attenuation.

Palavras Chave

3D printer; diagnostic radiology; Attenuation coefficient


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

Eduardo de Lima Correa, Maria da Penha Albuquerque Potiens, Leticia Lucente Campos Rodrigues

×

Avaliação da dep. energética de câmaras de ionização tipo lápis calibradas em feixes padrões de TC.

Metrologia em raios X, raios gama, elétrons e partículas carregadas


Resumo

O Laboratório de Calibração de Instrumentos do IPEN (LCI-IPEN), realiza calibrações de câmaras de ionização (CI) do tipo lápis utilizadas em medições de levantamento dosimétrico em sistemas clínicos de Tomografia Computadorizada (CT). Muitos usuários cometem equívocos ao utilizar uma câmara de ionização calibrada, na dosimetria de seus sistemas de CT. Neste trabalho foi estabelecida uma metodologia de determinação dos fatores de correção para qualidade (Kq) por meio da curva de calibração que é específica para cada câmara de ionização. Além disso, foi possível demonstrar a dependência energética existente nas CI do tipo lápis calibrada no LCI-IPEN.

Palavras Chave

dependência energética; tomografia computadorizada;calibração;


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

Maria da Penha Albuquerque Potiens

×

Avaliação das incertezas no processo de calibração cruzada de câmaras de placas paralelas

Metrologia em raios X, raios gama, elétrons e partículas carregadas


Resumo

Este estudo tem como objetivo estimar a incerteza padrão combinada para um detector de placas paralelas utilizadas para dosimetria de feixes de elétrons em aceleradores lineares para radioterapia, que foi calibrado pelo método de calibração cruzada. Ao manter a incerteza padrão combinada próxima da incerteza estabelecida no certificado de calibração da câmara de referência é possível estabelecer o fator de calibração do detector. A incerteza padrão combinada obtida neste trabalho foi de 2,5 %.

Palavras Chave

radioterapia; calibração; feixe de elétrons


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

Paulo Travassos, Max da Silva Ferreira, Samira Marques de Carvalho, Michele Maria da Silva, Hélio Augusto Salmon Jr, José Guilherme Pereira Peixoto

×

Avaliação de uma câmara de ionização tipo lápis especial pelo método de Monte Carlo

Metrologia e instrumentação em radiações ionizantes


Resumo

Uma câmara de ionização tipo lápis especial, desenvolvida no Instituto de Pesquisas Energéticas e Nucleares, foi caracterizada por meio de simulação de Monte Carlo para determinar a influência dos seus componentes na sua resposta. As principais diferenças entre esta câmara de ionização e as câmaras de ionização comerciais são relacionadas à sua configuração e os materiais constituintes. As simulações foram conduzidas empregando-se o código de Monte Carlo MCNP-4C. A maior influência obtida foi para o corpo de PMMA: 7,0%.

Palavras Chave

câmara de ionização; Monte Carlo; dosimetria; tomografia computadorizada


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

Dalila Mendonça, Lucio Pereira Neves, William S. Santos , Linda V. E. Caldas

×

Avaliação do desempenho de dosímetros eletrônicos para monitoração individual: testes em laboratório

Metrologia em raios X, raios gama, elétrons e partículas carregadas


Resumo

Os dosímetros eletrônicos baseados na tecnologia de armazenamento direto de íons vêm sendo utilizados amplamente em vários países para monitoramento individual em muitas aplicações das radiações ionizantes. Porém, seu uso como dosímetro de rotina tem sido estabelecido em poucos países devido à falta de programas de acreditação ou intercomparações. O objetivo deste trabalho é avaliar o desempenho de dois modelos de dosímetros de armazenamento direto de íons disponíveis no mercado internacional: o Miriom-Instadose-1 e o RADOS DIS-1 para eventualmente adotá-los na rotina de monitoramento individual no Brasil.

Palavras Chave

dosímetros eletrônicos; armazenamento direto de íons; monitoramento individual


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

Helen Jamil Khoury, Regina Bitelli Medeiros, Vinicius Saito Monteiro de Barros

×

Calibração de câmaras de ionização do tipo poço

Metrologia e instrumentação em radiações ionizantes


Resumo

Este artigo apresenta a metodologia desenvolvida pelo Laboratório de Ciências Radiológicas e atualmente em uso para a determinação do coeficiente de calibração para câmaras de ionização do tipo poço empregada na dosimetria das fontes de 192Ir de alta taxa de dose. A análise das incertezas envolvendo o procedimento de calibração são discutidos.

Palavras Chave

calibração; câmara de ionização tipo poço; dosimetria de fonte de 192Ir de alta taxa de dose


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

S P Leite, Evandro Jesus Pires, Luis Alexandre Gonçalves Magalhães, Mariano Gazineu David, Carlos Eduardo de Almeida, Renato Di Prinzio

×

Caracterização dos feixes de 60Co e 137Cs do Irradiador Shepherd 81 – 14D

Metrologia em raios X, raios gama, elétrons e partículas carregadas


Resumo

The objective of this work is the characterization of 60Co beams and the 137Cs irradiator Shepherd 81-14D acquired by the National Metrology Laboratory of Ionising Radiation of the Institute of Radiation Protection and Dosimetry (LNMRI /IRD), for use in calibration of measuring instruments of gamma radiation in air kerma and ambient dose equivalent, irradiation of films and TLD's. Field homogeneity measurements were carried out, calculated input and output time of the source and commissioning of sources.

Palavras Chave

air kerma; irradiator; radioprotection; ambient dose equivalent


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

Tânia Schirn Cabral

×

Caracterização e Implantação de Qualidades de Radiação Padronizadas em um Irradiador de Animais

Metrologia em raios X, raios gama, elétrons e partículas carregadas


Resumo

Este trabalho determinou a quantidade de filtros adicionais, para que o Irradiador de Animais do Laboratório de Ciências Radiológicas da UERJ opere em conformidade com a Norma NBR IEC 61267. Para a determinação destes filtros, foi necessário acoplar à janela do tubo de Raios X um sistema de posicionamento de filtros adicionais. Esta determinação foi realizada para que fosse obtida a 1ª camada semi redutora de acordo com os valores apresentados pela Norma IEC 61267. Foi utilizado o software SRS-78 do IPEM para estimar o valor da filtração total adicional através de medições dos valores da 1ª CSR.

Palavras Chave

Filtração Total; Camada Semi Redutora; IEC 61267


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

Samara Carvalho, Luis Magalhães

×

Characterization of a free air ionization chamber for low energies

Metrologia em raios X, raios gama, elétrons e partículas carregadas


Resumo

Free air ionization chambers are used by most primary metrology laboratories as primary standards of the quantities air kerma and exposure. The free air ionization chamber for low energies of the Calibration Laboratory (LCI) of IPEN showed in a characterization test a problem in the set responsible for the variation of its sensitive volume. After a modification in the support of the micrometers used for the movement of the internal cylinder and the establishment of a new alignment system protocol, the tests were redone. The objective of this work was to present the results obtained in the new condition.

Palavras Chave

free air ionization chamber; characterization tests; X-ray low energies


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

Natália Fiorini da Silva, Marcos Xavier, Vitor Vivolo

×

Comparação entre medidas de camada semirredutora: câmara de ionização vs medidores de estado sólido.

Metrologia em raios X, raios gama, elétrons e partículas carregadas


Resumo

Usualmente a camada semirredutora (CSR) é determinada utilizando-se câmara de ionização e filtros de alumínio. Entretanto, alguns multimedidores de estado sólido permitem a medida simultânea de diversos parâmetros do feixe de raios X, entre os quais a CSR. O objetivo deste estudo foi comparar os valores da CSR indicados por quatro diferentes multimedidores, com os valores medidos com câmara de ionização. A diferença máxima encontrada entre os dois métodos foi de 11,42%, para um dos medidores, o que mostra que o uso desses instrumentos para determinar CSR em raios X industrial deve ser objeto de uma avaliação mais criteriosa.

Palavras Chave

Camada semirredutora; Medidores de estado sólido; Radiodiagnóstico


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

Valéria Coêlho Costa Navarro, Marcus Vinícius Teixeira Navarro, Eric Matos Macedo

×

Comparação entre métodos de calibração do Produto kerma-área

Metrologia em raios X, raios gama, elétrons e partículas carregadas


Resumo

O PKA é uma relevante grandeza dosimétrica utilizada principalmente em procedimentos intervencionista, sendo importante sua calibração para a manutenção da confiabilidade metrológica. Como existem dois métodos para calibração desses medidores (método da substituição e método da medida direta do kerma e área), o objetivo do estudo foi comparar esses métodos, visando indicar qual a melhor opção a ser implantado no Laboratório Labprosaud/IFBA. Os resultados revelaram boa equivalência dos métodos, com concordância mínima de 99,2% entre os fatores de calibração. Entretanto, o método de calibração por substituição assegura maior confiabilidade metrológica, com incertezas 60% menores, tendo sido implantado no Labprosaud.

Palavras Chave

Produto Kerma-área (PKA); Calibração de medidores de PKA; Confiabilidade metrológica.


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

Éric Macêdo, Lara Catrine Silva Pereira, Igor Fernando Modesto Garcia, MÁRIO DE JESUS FERREIRA, Marcus Vinícius Teixeira Navarro

×

Comparison of surface contamination monitors for in vivo measurement of 131-I in thyroid

Metrologia nas áreas de saúde, indústria e proteção radiológica


Resumo

The routine handling of radiopharmaceuticals in nuclear medicine represents a significant risk of internal exposure to the staff. The IAEA recommends the implementation of monitoring plans for all workers subject to a risk of exposures above 1 mSv per year. However, in Brazil, such recommendation is practically unfeasible due to the lack of a sufficient number of qualified internal dosimetry services over the country. This work presents an alternative based on a simple and inexpensive methodology aimed to perform in-vivo monitoring of 131-I in thyroid using portable surface contamination probes. All models evaluated showed suitable sensitivity for such application.

Palavras Chave

Internal dosimetry; iodine-131; radiation protection; nuclear medicine.


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

Bernardo Maranhão Dantas, ANA LETÍCIA ALMEIDA DANTAS

×

Conhecendo a potencia de um equipamento de raios x

Metrologia em raios X, raios gama, elétrons e partículas carregadas


Resumo

Após levantarmos uma curva de resposta de potência em função da carga para o equipamento de Raios X, definimos a região de operação experimental e comparamos com a teórica, e assim concluímos que é de suma importância para operação do equipamento de Raios X, pois pode definir a quantidade de dose que o paciente receberá em uma futura exposição e o limiar de operação, para que o equipamento não seja extrapolado e venha a sofrer um dano. Para a mesma potência nominal, existe uma diferença de 0,99% entre as leituras encontradas numa mesma potência de operação.

Palavras Chave

raios x; potencia; kerma


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

LUCIO DAS CHAGAS DE ANDRADE, JOSE GUILHERME PEIREIRA

×

Controle da qualidade do 99mTc

Metrologia e instrumentação em radiações ionizantes


Resumo

O radiofármaco mais utilizado na medicina nuclear é o tecnécio-99m. Os radiofármacos marcados com 99mTc são os principais agentes para diagnóstico, sendo utilizados na grande maioria dos procedimentos, devido às características do radionuclídeo. Durante seu preparo podem ser geradas impurezas que formam produtos com qualidades diferentes das desejadas. No presente trabalho foram apresentados alguns dos fatores que podem interferir nos radiofármacos e os testes utilizados para garantir sua qualidade, certificando que o produto esteja adequado ao propósito. Cabe aos serviços de medicina nuclear implantarem um programa para elevar a qualidade dos exames e aumentar a segurança dos pacientes.

Palavras Chave

Medicina nuclear; Radiofármaco; Controle da qualidade


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

Sanny Miranda Alves, Giovane de Jesus Teixeira, Carlos Henrique Simões de Souza

×

Controle de qualidade e estabilidade de dosímetros usados em radioterapia empregando fontes de 137Cs

Metrologia e instrumentação em radiações ionizantes


Resumo

O dispositivo de verificação emprega fontes de braquiterapia de 137Cs que não podem mais serem utilizadas para tratamento e tem como objetivo dar subsídio aos usuários de forma a permitir o controle da estabilidade ao longo do tempo das câmaras de ionização utilizadas em radioterapia e atender às exigências da CNEN e ANVISA. Como não há equipamento similar que está sendo produzido no mercado brasileiro, e o controle de estabilidade é parte de uma exigência de licenciamento, este dispositivo foi construído para atender às necessidades dos vários centros de radioterapia.

Palavras Chave

dispositivo de verificação; controle de qualidade e estabilidade; controle de dosímetros para radioterapia


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

V Mondaini C, S P Leite, Evandro Jesus Pires, Luis Alexandre Gonçalves Magalhães, Mariano Gazineu David, Carlos Eduardo de Almeida, Renato Di Prinzio

×

Desenvolvimento das Condições de Radiação em Tomografia Computadorizada - TC

Metrologia em raios X, raios gama, elétrons e partículas carregadas


Resumo

: O LNMRI está implantando as qualidades em CT, utilizadas na calibração das câmaras utilizadas em hospitais e clínicas. Os resultados preliminares do estudo, apresentou uma variação para a Qualidade RQT 9 entre 1,350x107 e 1,343x107 Gy/C dentro das incertezas expandidas avaliadas na ordem de 1,61 e 1,70 %.

Palavras Chave

calibração; tomografia computadorizada; qualidades


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

José Guilherme Pereira Peixoto

×

Desenvolvimento de um relógio digital com arduino utilizando base de tempo rastreável

Metrologia em raios X, raios gama, elétrons e partículas carregadas


Resumo

O relógio digital tem sua base de tempo fornecida por um Quartzo, tendo, com isso, uma incerteza elevada. Logo o desenvolvimento de um relógio digital com base de tempo fornecido por um contador de Rubídio, rastreado ao Observatório Nacional, reduz a incerteza nas medições do tempo utilizando o relógio externo comparado com o relógio do computador.

Palavras Chave

Relógio; Tempo; Incerteza.


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

José Guilherme Pereira Peixoto, Ricardo José de Carvalho, Daniel da Silva Quaresma

×

Determinação da taxa de kerma no ar de referência para 192Ir de alta taxa de dose para braquiterapia

Metrologia e instrumentação em radiações ionizantes


Resumo

Este artigo apresenta a metodologia desenvolvida pelo Laboratório de Ciências Radiológicas e atualmente em uso para a determinação da taxa de kerma no ar de fontes de 192Ir de alta taxa de dose para calibrar as câmaras do tipo poço. A análise das incertezas envolvendo o procedimento de medições são apresentados.

Palavras Chave

calibração; taxa de kerma no ar de referência; fonte de 192Ir de alta taxa de dose para braquiterapia


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

Evandro Jesus Pires, Renato Di Prinzio, S P Leite, Luis Alexandre Gonçalves Magalhães, Mariano Gazineu David, Carlos Eduardo de Almeida

×

Determinação da tensão aplicada em um tubo de raios X através do espectro

Metrologia em raios X, raios gama, elétrons e partículas carregadas


Resumo

Esse trabalho mostra a metodologia usada para determinação da tensão aplicada em um tubo de raios X utilizando seus espectros. As medidas foram feitas usando um detector de Telureto de Cádmio. Antes das medidas serem realizadas o detector foi calibrado com uma fonte de Am241. Depois de obtidos os espectros, foram calculadas as energias médias, o potencial de aceleração dos elétrons (kVp) de cada espectro e construido uma reta de calibração para o kVp desse tubo.

Palavras Chave

controle de qualidade; raios x; kVp


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

Trabalho sem CoAutores

×

Determinação do centro efetivo de um detector Long Counter no Laboratório de Metrologia de Nêutrons.

Metrologia em raios X, raios gama, elétrons e partículas carregadas


Resumo

A avaliação do centro efetivo de um detector tipo De Pangher Long Counter para um conjunto de fontes de radionuclídeos corresponde a um dos parâmetros para sua caracterização. Neste trabalho são apresentados os resultados da avaliação do centro efetivo deste detector, preenchido com gás 3He, para duas fontes de radionuclídeos com espectros bem definidos de 241AmBe e 252Cf . As medições foram realizadas no salão de baixo espalhamento do Laboratório de Metrologia de Nêutrons (LN) pertencente ao Instituto de Radioproteção e Dosimetria (IRD).

Palavras Chave

1. centro efetivo; 2.De Pangher Long Counter 3; Fluência de nêutrons


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

KARLA CRISTINA DE SOUZA PATRÃO, Evaldo Simões da Fonseca, Walsan Wagner Pereira, Ricardo Tadeu Lopes

×

Determinação do rendimento químico na dosimetria Fricke para fontes de 192Ir usadas em braquiterapia

Metrologia em raios X, raios gama, elétrons e partículas carregadas


Resumo

Com o objetivo de desenvolver um padrão primário de dose absorvida na água para fontes de 192Ir usadas em braquiterapia de alta taxa de dose, este trabalho enfoca a determinação do rendimento químico, G(Fe+3), na dosimetria Fricke para a energia desta fonte. Foram determinados os valores de G(Fe+3) para três qualidades de feixes de raios-x (150, 250 e 300 kV) e para o 60Co. O valor de G(Fe+3) para a energia média do 192Ir foi obtido por ajuste linear, resultando em 1,555 ± 0,015 ?mol/J.

Palavras Chave

rendimento químico; dosimetria Fricke; braquiterapia


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

Camila Salata, Paulo Henrique Rosado, Marcos Aurélio Gomes de Albuquerque, Carlos Eduardo de Almeida

×

Determination of correlated uncertainties of sestamibi- 99mTc marking

Metrologia em raios X, raios gama, elétrons e partículas carregadas


Resumo

The input quantities determination involved in sestamibi-99mTc marking used in heart scans allowed to estimate the combined and associated standard uncertainty with the process. The U value demonstrated that any parameter of the quality control process can be compared and correlated to obtain a real value and validation method, indicating or not, the adequacy of institutional practices and reinforcing the importance of the uncertainties associated to the results in medicine.

Palavras Chave

sestamibi; uncertainties expanded; input quantities


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

Alexandre Gama, Giovane de Jesus Teixeira, José Guilherme Pereira Peixoto

×

Determination of the 121Te gamma emission probabilities associated to radiopharmaceutical NaI[123I]

Metrologia em raios X, raios gama, elétrons e partículas carregadas


Resumo

The 123I is widely used in medical radiology procedures nuclear . According to Pharmacopoeia there must be a care around its production process , since it can be generated radionuclídcas impurities. 121Te is an impurity that arises during the production process, and determination of range emission probabilities ( P? ) is important so that they have available more information on the data of its decay . Also obtained was a absolute standardization using the peak - sum and the comparison method of values ??obtained with the efficiency curve method.

Palavras Chave

emission probability; 121Te; absolute standardization; sum-peak method; radiopharmaceutical


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

R. Poledna, José Ubiratan Delgado, Maria Cândida de Almeida, Ricardo Tadeu Lopes, Ronaldo Lins

×

DETERMINATION OF THE TRUE NULL ELECTRODE SPACING OF AN EXTRAPOLATION CHAMBER FOR X-RAY DOSIMETRY

Metrologia em raios X, raios gama, elétrons e partículas carregadas


Resumo

The concept of the true null electrode spacing is used to define the sensitive volume of an extrapolation chamber. In this paper, a critical analysis of two methodologies for determining the true null electrode spacing of an extrapolation chamber was done. Firstly, the ionization current as a function of electrode spacing was measured. In the second procedure was measured the capacitance between the electrodes of a 23392 Böhm model PTW ionization chamber and a reliable relationship between capacitance and relative distance was established. Results showed that the true null spacing values varied from 0.0015 to 0.38 mm

Palavras Chave

Extrapolation chamber;true null spacing; dosimetry


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

F.M.Bastos, Teógenes Augusto da Silva

×

Development and evaluation of a technique for in vivo monitoring of 60Co in the lungs

Metrologia em raios X, raios gama, elétrons e partículas carregadas


Resumo

60Co is a fission product of 235U and represents a risk of internal exposure of workers in nuclear power plants, especially those involved in the maintenance of potentially contaminated parts and equipment. The control of 60Co intake by inhalation can be performed through in vivo monitoring. This work describes the evaluation of a technique through the minimum detectable activity and the corresponding minimum detectable effective doses, based on biokinetic and dosimetric models of 60Co in the human body. The results allow to state that the technique is suitable either for monitoring of occupational exposures or evaluation of accidental intakes.

Palavras Chave

radionuclide; incorporation; 60Co; internal dosimetry; nuclear energy


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

Eder Augusto Lucena, ANA LETÍCIA ALMEIDA DANTAS, Bernardo Maranhão Dantas

×

Estudo das condições de radiação para obtenção do feixe padrão em tomografia computadorizada

Metrologia em raios X, raios gama, elétrons e partículas carregadas


Resumo

No Brasil existe a necessidade de expandir a rastreabilidade na calibração de câmaras utilizadas na dosimetria em CT. Desta forma, com o objetivo de promover a expansão das condições de radiação RQT, o LNMRI disseminará esta grandeza. Essas condições de radiação podem ser caracterizadas em termos de tensão no tubo de raios X (PPV), primeira camada semi-redutora (1ª CSR) e coeficiente de homogeneidade (CH). O LNMRI apresentou resultados satisfatórios dentro das especificações internacionais sugeridas pela IEC 61267 e TRS 457.

Palavras Chave

qualidade de radiação RQT; Tomografia computadorizada; CT.


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

José Gulherme Pereira Peixoto

×

Estudo de uma nova matriz vítrea pela técnica de termoluminescência

Metrologia em raios X, raios gama, elétrons e partículas carregadas


Resumo

A técnica de termoluminescência é muito utilizada tanto para dosimetria pessoal quanto para dosimetria de doses altas. Neste trabalho, a técnica de termoluminescência foi utilizada para estudar uma nova matriz vítrea, com composição nominal de 20Li2CO3.10Al2O3.20BaO.50B2O3 (mol%), irradiada com diferentes doses em uma fonte de 60Co. As curvas de emissão termoluminescente e a curva de dose-resposta foram obtidas para doses de radiação entre 50 Gy e 900 Gy. Os resultados obtidos mostraram que esta nova matriz vítrea apresenta uso potencial em dosimetria de altas doses.

Palavras Chave

dosimetria; termoluminescência; novos materiais


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

Pâmela Z. Ferreira, Uly P. Vedovato, Diego M. da Cunha, Noelio O. Dantas, Anielle C. A. Silva, Lucio Pereira Neves, Linda V. E. Caldas, Betzabel N. S. Carrera, Shigueo Watanabe

×

Exercício de Comparação Laboratorial 2013-2015

Metrologia em raios X, raios gama, elétrons e partículas carregadas


Resumo

This work deals with the preliminary results of the second exercise of comparing the radiation monitors calibration laboratories in Brazil. The exercise involved eight laboratories and the measured quantity is the air kerma in a beam of 137Cs for radioprotection. The exercise was conducted by the LNMRI/IRD, in a star-shaped arrangement from October 2013 to July 2015. The largest deviation was 2% of the calibration coefficient that is acceptable for applications in radioprotection.

Palavras Chave

Air Kerma; comparison; radioprotection


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

Maria da Penha Albuquerque Potiens, CMA Soares, Renata Ramos da Silveira, Helen Jamil Khoury, E Fernandes, WS Santos, JC Borges

×

Experimental and Monte Carlo evaluation of an ionization chamber in a 60Co beam

Metrologia e instrumentação em radiações ionizantes


Resumo

Recently a special parallel-plate ionization chamber was developed and characterized at the Instituto de Pesquisas Energéticas e Nucleares. The operational tests presented results within the recommended limits. In order to determine the influence of some components of the ionization chamber on its response, Monte Carlo simulations were carried out. The experimental and simulation results pointed out that the dosimeter evaluated in the present work has favorable properties to be applied to 60Co dosimetry at calibration laboratories.

Palavras Chave

dosimetry; 60Co beams; ionization chamber; Monte Carlo simulation


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

Lucio Pereira Neves, William S. Santos , Linda V. E. Caldas

×

Implantação de método não invasivo para calibração de medidores de tensão de pico (kVp)

Metrologia em raios X, raios gama, elétrons e partículas carregadas


Resumo

Controle de qualidade no radiodiagnóstico é um dos mecanismos que minimizam as exposições às radiações ionizantes, sendo a medida da tensão do tubo um dos principais testes. Por isso, a calibração dos medidores não invasivos de tensão é imprescindível para manter a confiabilidade metrológica, dos testes de controle de qualidade. Assim, esse trabalho descreve a implantação no LABPROSAUD-IFBA, da metodologia de calibração da grandeza tensão de pico pelo método da substituição, utilizando medidor padrão não invasivo. Os resultados revelaram ótimo desempenho quando comparados às calibrações com métodos invasivos, apresentando diferença máxima de 4%, contemplada nos intervalos das incertezas das calibrações.

Palavras Chave

Tensão de Pico; Medidores não invasivos de tensão; Calibração por substituição; Controle de qualidade.


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

Valéria Coêlho Costa Navarro, Marcus Vinícius Teixeira Navarro, Igor Fernando Modesto Garcia, Lara Catrine Silva Pereira

×

Implementação do método pico-soma para padronização de radionuclídeos emissores de pósitrons

Metrologia de radionuclídeos


Resumo

A tomografia por emissão de pósitrons (PET) está sendo cada vez mais reconhecida como uma importante ferramenta de imagem quantitativa para diagnóstico e avaliação da resposta à terapia. Como a administração correta da dose desempenha um papel crucial na medicina nuclear, é importante que os instrumentos utilizados para verificar a atividade dos radionuclídeos de meia-vida curta sejam calibrados com exatidão e rastreáveis a padrões nacionais e internacionais. O método pico-soma tem sido amplamente utilizado para padronização de radionuclídeos. O propósito deste trabalho foi implementar a metodologia para padronização de radiofármacos PET no Centro Regional de Ciências Nucleares do Nordeste (CRCN-NE).

Palavras Chave

radiofármacos; metrologia; pico-soma; espectrometria gama


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

Mércia Liane de Oliveira, Fernando Roberto de Andrade Lima

×

Influence of the exposure time in the area monitors at radiodiagnostic

Metrologia em raios X, raios gama, elétrons e partículas carregadas


Resumo

Area monitoring ensures radiation exposure at an acceptable level, which must be lower than legal limit. Experimental measurements were taken in a ionizing radiation calibration laboratory. The specified reference radiation to radiation protection N80 was used. Five area monitors were used. The ranges of dose rate inaccuracy measured in rate mode for times ? 2 and ? 3 s were from 10 to 48 % and from 1 to 15 %, respectively. The inaccuracy ranges measured in integrated mode for times ? 2 and ? 3 s were from 4 to 8 % and from 0 to 22 %, respectively.

Palavras Chave

Area monitoring; Radiodiagnostic; Occupational exposure


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

Marcus Vinícius Teixeira Navarro, Eric Matos Macedo, MÁRIO DE JESUS FERREIRA, Valéria Coêlho Costa Navarro, Igor Fernando Modesto Garcia, Lara Catrine Silva Pereira

×

Influence of the radioactive source position inside the well-type ionization chamber

Metrologia de radionuclídeos


Resumo

The activimeter, instrument used in radionuclide activity measurement, consists primarily of a well type ionization chamber coupled to a special electronic device. Its response, after calibration, is shown in activity units (Becquerel or Curie). The goal of this study is to verify radioactive source position influence over activity measured by this instrument. Radioactive sources measurements were made at different depths inside the ionization chamber well. Results showed maximum variation of -23 %, -28 % and -15 % for 57Co, 133Ba and 137Cs, respectively

Palavras Chave

activity meter; nuclear medicine; control quality


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

Eduardo de Lima Correa, Maria da Penha Albuquerque Potiens

×

IRD-CNEN-WBC capabilities for in vivo monitoring of internally deposited radionuclides in human body

Metrologia nas áreas de saúde, indústria e proteção radiológica


Resumo

Internal exposure to radionuclides may occur as a result of a variety of practices, such as in nuclear industry; production of radiopharmaceuticals and nuclear medicine, biological research and agriculture; as well as in mining and milling of minerals with associated NORM. The IRD whole-body counter is equipped with four HPGe detectors and two NaI(Tl). The detection systems are able to detect and quantify a large variety of radionuclides emitting photons in the energy range from 10 to 3000 keV. The minimum detectable activities for most of the radionuclides of interest allow occupational monitoring as well evaluation of accidental intakes.

Palavras Chave

internal dosimetry; in vivo measurement; whole-body counter


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

Bernardo Maranhão Dantas, Eder Augusto Lucena

×

Levantamento radiométrico em mamografia: problemas e desafios.

Metrologia em raios X, raios gama, elétrons e partículas carregadas


Resumo

Além de ser obrigatório, o levantamento radiométrico continua sendo uma necessidade devido a construção de salas cada vez menores, podendo as condições de calibração, a instrumentação e seu uso, produzirem fatores subestimados. As medidas realizadas no Labprosaud/IFBA, com cinco diferentes instrumentos e para a qualidade ISO N 25, mostram a possibilidade dos valores apresentados nos levantamentos radiométricos estarem subestimado em até 10 vezes. Os resultados indicam a necessidade dos equipamentos de medida serem calibrados nas qualidades ISO N, na faixa de energia de mamografia, no modo dose integrada e com tempos de exposição menores que 1 s.

Palavras Chave

Levantamento Radiométrico; Mamografia; Calibração.


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

Valéria Navarro, Igor Fernando Modesto Garcia, MÁRIO DE JESUS FERREIRA, Igor Fernando Modesto Garcia

×

Mammography calibration qualities establishment in a Mo-Mo clinical system

Metrologia e instrumentação em radiações ionizantes


Resumo

In this study the mammography calibration qualities were established in a clinical mammography system. The objective is to provide the IPEN instruments calibration laboratory with both mammography calibration methods (using a clinical and an industrial system). The results showed a good behavior of mammography equipment, in terms of kVp, PPV and exposure time. The additional filtration of molybdenum is adequate, air-kerma rates were determined and spectra were obtained.

Palavras Chave

Instrument calibration; mammography; diagnostic radiology; quality control.


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

Lucas Rodrigues dos Santos, Vitor Vivolo, Maria da Penha Albuquerque Potiens

×

MCNP simulation of the incident and albedo neutron response of the IRD albedo neutron dosemeter

Metrologia em raios X, raios gama, elétrons e partículas carregadas


Resumo

The IRD TLD albedo dosemeter measures both incident and albedo neutron component. The incident to albedo ratio is used to take into account the energy dependence of its response. In this paper, the behavior of the IRD albedo dosemeter response as a function of the incident to albedo ratio for 241Am–Be sources was simulated to improve its algorithm. The simulation was performed in MCNPX transport code and presents a good agreement with experimental measurements. The results obtained in this work are very useful to improve the accuracy of the IRD albedo dosemeter at real neutron workplace.

Palavras Chave

albedo neutron dosemeter; Monte Carlo simulation; calibration


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

Bruno Mendes Freitas , Marcelo Marques Martins, Ademir Xavier. da Silva

×

Methodology for calibration of ionization chambers for X-ray of low energy in absorbed dose to water

Metrologia nas áreas de saúde, indústria e proteção radiológica


Resumo

The beams of low energy X-ray (10 to 150 kV) are used in several places in the world to treat a wide variety of surface disorders, and between these malignancies. As in Brazil, at this moment, there is no calibration laboratory providing the control service or calibration of parallel plate ionization chambers, the aim of this project was to establish a methodology for calibration of this kind of ionization chambers at low energy X-ray beams in terms of absorbed dose to water using simulators in the LCI.

Palavras Chave

X-rays; radiotherapy; calibration; ionization chamber; absorbed dose


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

Vitor Vivolo, Maria da Penha Albuquerque Potiens

×

Método Alternativo de Irradiação da Solução de MnSO4 por Fonte de PuBe para Medições de Eficiência

Metrologia e instrumentação em radiações ionizantes


Resumo

Este estudo propõe criar, através do método de Monte Carlo, um sistema de irradiação alternativo para a solução de Sulfato de Manganês utilizando uma fonte de Plutônio-Berílio. Buscando eliminar a problemática de institutos de pesquisa que não possuem reatores ou aceleradores de nêutrons em sua infraestrutura, otimizando e oferecendo independência aos mesmos para realizarem medições de eficiência da solução de MnSO4 em sua própria localidade. As características deste novo sistema foram definidas através de simulações computacionais para que a solução atingisse a máxima captura de nêutrons pelo manganês da solução.

Palavras Chave

Irradiação; Nêutrons; MCNP; Banho de Sulfato de Manganês


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

Marcelo Marques Martins, Walsan Wagner Pereira

×

Método Alternativo de Irradiação da Solução de MnSO4 por Fonte de PuBe para Medições de Eficiência

Metrologia e instrumentação em radiações ionizantes


Resumo

Este estudo propõe criar, através do método de Monte Carlo, um sistema de irradiação alternativo para a solução de Sulfato de Manganês utilizando uma fonte de Plutônio-Berílio. Buscando eliminar a problemática de institutos de pesquisa que não possuem reatores ou aceleradores de nêutrons em sua infraestrutura, otimizando e oferecendo independência aos mesmos para realizarem medições de eficiência da solução de MnSO4 em sua própria localidade. As características deste novo sistema foram definidas através de simulações computacionais para que a solução atingisse a máxima captura de nêutrons pelo manganês da solução.

Palavras Chave

Irradiação; Nêutrons; MCNP; Banho de Sulfato de Manganês


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

Marcelo Marques Martins, Walsan Wagner Pereira

×

Metrological activity determination of Ba-133 by sum-peak absolute method

Metrologia de radionuclídeos


Resumo

The National Laboratory for Metrology of Ionizing Radiation provides gamma sources of radionuclide and standardized in activity with reduced uncertainties. Relative methods require standards to determine the sample activity while the absolute methods, as sum-peak, not . The activity is obtained directly with good accuracy and low uncertainties. Ba-133 is used in research laboratories and on calibration of detectors for analysis in different work areas. Classical absolute methods don`t calibrate Ba-133 due to its complex decay scheme. The sum-peak method using gamma spectrometry with germanium detector standardizes Ba-133 samples. Uncertainties lower than 1% to activity results were obtained .

Palavras Chave

sum-peak method; Ba-133; gamma spectrometry


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

R. L. da Silva, J. U. Delgado, R. Poledna, A. Santos, E. V. de Veras , J. Rangel, O. L. Trindade

×

New thermal neutron calibration channel at LNMRI/IRD

Metrologia de nêutrons


Resumo

A new standard thermal neutron flux unit was designed in the National Ionizing Radiation Metrology Laboratory (LNMRI) for calibration of neutron detectors. Fluence is achieved by moderation of four 241Am-Be sources with 596 GBq each, in a facility built with graphite and paraffin blocks. The study was divided into two stages. Firstly, simulations were performed using MCNPX code in different geometric arrangements, seeking the best performance in terms of fluence and their uncertainties. Last, the system was assembled based on the results obtained on the simulations. The simulation results indicate quasi-homogeneous fluence (1%) in the central chamber.

Palavras Chave

Neutron Metrology; Neutron Fluence; Monte Carlo Simulation; Calibration.


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

KARLA CRISTINA DE SOUZA PATRÃO, Evaldo Simões da Fonseca, Walsan Wagner Pereira, Ricardo Tadeu Lopes

×

On the response of electronic personal dosimeters in constant potential and pulsed x-ray beams

Metrologia em raios X, raios gama, elétrons e partículas carregadas


Resumo

Electronic personal dosimeters (EPDs) based on solid state detectors have widely been used but some deficiencies in their response in pulsed radiation beams have been reported. Nowadays, there is not an international standard for pulsed X-ray beams for calibration or type testing of dosimeters. Irradiation conditions for testing the response of EPDs in both the constant potential and pulsed X-ray beams were established in CDTN. Three different types of EPDs were tested in different conditions in similar ISO and IEC X-ray qualities. Results stressed the need of performing additional checks before using EPDs in constant potential or pulsed X-rays

Palavras Chave

electronic personal dosemeters; EPD; continuous X-ray; pulsed X-ray; dosimeter performance


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

Claudete R. E. Silva, Paulo Márcio C. de Oliveira

×

OSL response bleaching of BeO samples, using fluorescent light and blue LEDs

Metrologia e instrumentação em radiações ionizantes


Resumo

The optically stimulated luminescence (OSL) is widely used as a dosimetric technique for many applications. In this work, the OSL response bleaching of BeO samples was studied. The samples were irradiated using a beta radiation source (90Sr+90Y); the bleaching treatments (fluorescent light and blue LEDs) were performed, and the results were compared. Various optical treatment time intervals were tested until reaching the complete bleaching of the OSL response. The best combination of the time interval and bleaching type was analyzed.

Palavras Chave

optically stimulated luminescence; bleaching treatment; beryllium oxide


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

Linda V. E. Caldas

×

Padronização absoluta do 106Ru pelo método de anticoincidência.

Metrologia de radionuclídeos


Resumo

O sistema de padronização absoluta da grandeza atividade pela técnica de anticoincidência e cronometragem em tempo vivo foi implementado no LNMRI em 2008 para diminuir os impactos de alguns fatores que influenciavam na medição da atividade pela técnica de contagem em coincidência, usada há décadas no laboratório, como por exemplo, o tempo de medição. Com o sistema de anti-coincidência, a variedade de radionuclídeos que podem ser calibrados pelo LNMRI, em relação ao tipo de decaimento, aumentou. O objetivo deste trabalho é a padronização do 106Ru pelo método de contagem em anticoincidência, bem como estimar as suas incertezas de medição.

Palavras Chave

Método de Anticoincidência; Medição Absoluta da Atividade; Metrologia de Radionuclídeos


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

Trabalho sem CoAutores

×

Padronização do 57Co por diferentes métodos do LNMRI.

Metrologia em raios X, raios gama, elétrons e partículas carregadas


Resumo

A atividade de uma solução de 57Co foi determinada por quatro métodos de medição do LNMRI. A solução foi padronizada pelo método de anti-coincidência com cronometragem em tempo vivo e pelo método pico-soma. Os métodos de curva de eficiência e comparação padrão-amostra também foram usados nessa comparação. Os resultados encontrados e suas incertezas de medição mostram que os métodos são equivalentes.

Palavras Chave

Método de Anticoincidência; Método Pico-soma; Curva de Eficiência; Medição de Atividade; Metrologia de Radionuclídeos


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

Trabalho sem CoAutores

×

Performance of the Participant Labs in the Nat. Intercomp Program PNI in the Period from 1991 - 2013

Educação em metrologia, normalização e avaliação da conformidade


Resumo

The statistical evaluation of the data of 23 years of the Brazilian Intercomparison Program shows the performance of the 24 participant Laboratories of the country in the determination of 29 radionuclides in 10600 spiked samples of low level activity values. The results were shown a good performance and an evolution of the quality control for analyses of this kind of samples in this time period.

Palavras Chave

Quality Control Program;Activity measurements radionuclides in environmental samples; National Intercomparison Program (PNI); Performance of the Brazilian Laboratories.


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

Luiz Tauhata, Maria Elizabeth Couto Machado Vianna, Antonio Eduardo de Oliveira, Ana Cristina de Melo Ferreira

×

Performance of three pencil-type ionization chambers (10 cm) in computed tomography standard beams

Metrologia em raios X, raios gama, elétrons e partículas carregadas


Resumo

The use of computed tomography (CT) has increased over the years, thus generating a concern about the doses received by patients undergoing this procedure. Therefore, it is necessary to perform routinely beam dosimetry with the use of a pencil-type ionization chamber. This detector is the most utilized in the procedures of quality control tests on this kind of equipment. The objective of this work was to perform some characterization tests in standard CT beams, as the saturation curve, polarity effect, ion collection efficiency and linearity of response, using three ionization chambers, one commercial and two developed at the IPEN.

Palavras Chave

Dosimetry; ionization chamber; computed tomography


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

Maysa Costa de Castro, Marcos Xavier

×

Phantom positioning variation in the Gamma Knife® Perfexion dosimetry

Metrologia em raios X, raios gama, elétrons e partículas carregadas


Resumo

The use of small volume ionization chamber has become required for the dosimetry of equipments that use small radiation fields. A pinpoint ionization chamber is ideal for the dosimetry of a Gamma Knife® Perfexion (GKP) unit. In this work, this chamber was inserted into the phantom, and measurements were performed with the phantom in different positions, in order to verify if the change in the phantom positioning affects the dosimetry of the GKP. Three different phantom positions were performed. The variation in the result is within the range allowed for the dosimetry of a GKP equipment.

Palavras Chave

gamma knife; pinpoint ionization chamber; dosimetry


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

Maria da Penha Albuquerque Potiens, Crystian Saraiva

×

Pilot study: relative dose of the TLD, OSL and Radiochromic film applied in CT exams dosimetry

Metrologia nas áreas de saúde, indústria e proteção radiológica


Resumo

At DDI/UNIFESP, the abdomen and chest CT exams correspond to 38% of the exams, becoming the focus of studies. The aim of this study is to assess the relative dose using TLDs, OSLs and RF for the evaluation of the dose distribution in the skin in abdomen CT exams. The simulation of the CT exam was performed in an anthropomorphic phantom, using a CT scanner Philips, Brilliance/64 and TLDs, OSLs and RF fixed along the sagittal axis of the phantom. The OSLs showed similar performance to the TLDs and RF shows low accuracy, resulting in an average value (0.927±0.022).

Palavras Chave

computed tomography; abdomen; dosimetry


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

Cristina Faria Kikuti, Rodrigo Seiki Inoue Maia, Ricardo Francisco Tavares Romani

×

Portable meter study of ionizing radiation Teletector in high rates of air kerma.

Metrologia e instrumentação em radiações ionizantes


Resumo

A set of portable meters of ionizing radiation high rates of air kerma (teletectors) commonly used in emergencies in Brazil and sent to the Calibration Laboratory of IPEN were under several tests and analyst is parameters for the detectors behavior were established. Applied tests were: energy dependence and primarily overload with the new irradiation system. Thus it was possible to determine the most common characteristic found in these equipments (quality control programs) and new calibration criteria were established following international recommendations.

Palavras Chave

portable meters; calibration; overload; quality control.


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

Maria da Penha A. Potiens, Vitor Vivolo

×

Protocolo técnico da comparação bilateral em Radiologia Diagnóstica: Parte 1

Metrologia em raios X, raios gama, elétrons e partículas carregadas


Resumo

Conforme dados obtidos pelo www.datasus.gov.br, c confirma-se a necessidade de que a disseminação de cada condição de radiação seja verificada periodicamente, desta forma a comparação bilateral entre os laboratórios de calibração torna-se mandatória na garantia da qualidade dos serviços.

Palavras Chave

comparação; padronização; rastreabilibade; incerteza; sistema da qualidade


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

Carlos Eduardo de Almeida

×

Protocolo técnico da comparação bilateral em Radiologia Diagnóstica: Parte 2.

Metrologia em raios X, raios gama, elétrons e partículas carregadas


Resumo

A Radiologia convencional (?70%), mamografia (?4%) e tomografia computadorizada (?2%) farão parte desta comparação bilateral. Estará descrito as câmaras de ionização utilizadas, as condições de radiação e referência, a agenda e os custos envolvidos. Os resultados parciais serão apresentados nos congressos de metrologia e física médica.

Palavras Chave

comparação; padronização; rastreabilibade; incerteza; sistema da qualidade


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

Carlos Eduardo de Almeida

×

Protocolo técnico da comparação bilateral em Radiologia Diagnóstica: Parte 3.

Metrologia em raios X, raios gama, elétrons e partículas carregadas


Resumo

Devido a necessidade de homogeneizar os resultados e a avaliação de incertezas do protocolo técnico da comparação bilateral, foram selecionados não somente os equipamentos utilizados, as condições de referência e uma planilha que pudesse servir a todos os laboratórios, bem como uma base para homogeneizar a comparação. Os resultados parciais serão apresentados nos congressos de metrologia e física médica.

Palavras Chave

comparação; padronização; rastreabilibade; incerteza; sistema da qualidade


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

Carlos Eduardo de Almeida

×

Reference factor "F" _(?"(CT)" ?_"Q" ) and X ray tube ionization yield "R" _(?"(TUBE)" ?_"Q" )

Metrologia em raios X, raios gama, elétrons e partículas carregadas


Resumo

The operational facility procedures in diagnostic radiology standardization and calibration, through the relation between the X ray tube current and the ionization chamber current in a radiation quality Q, shown the reference factor "F" _(?"(CT)" ?_"Q" ) as the reality estimate to the X ray tube ionization yield, "R" _(?"(TUBE)" ?_"Q" ).

Palavras Chave

Radiation quality; X ray tube; reference factor; ionization yield


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

Ricardo de Souza Cardoso, José Guilherme Pereira Peixoto

×

Results of an innovative methodology to the dosimetry in mammography examinations

Metrologia em raios X, raios gama, elétrons e partículas carregadas


Resumo

Female breast is a radiosensitive organ and the main procedure to assess the carcinogenic risk associated the mammographic practices has been indicated by the mean glandular dose (MGD) measurements. However, this dosimetric quantity may not provide the accuracy required for such measurements due to the heterogeneity of glandular tissue. So twenty-one exposures happened in a phantom mammographic using a CR equipment. Results were compared with data from the literature and was found an accuracy rate 15% lower than the recommended level. Experimental values reached below the IAEA’s acceptable levels for 3.0 to 6.0 cm thickness of the compressed breast.

Palavras Chave

mammography phantom; mean glandular dose; medical radiodiagnostic; metrology


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

José Ubiratan Delgado, José Guilherme Pereira Peixoto, Ricardo Tadeu Lopes

×

Results of an innovative methodology to the dosimetry in mammography examinations

Metrologia em raios X, raios gama, elétrons e partículas carregadas


Resumo

Female breast is a radiosensitive organ and the main procedure to assess the carcinogenic risk associated the mammographic practices has been indicated by the mean glandular dose (MGD) measurements. However, this dosimetric quantity may not provide the accuracy required for such measurements due to the heterogeneity of glandular tissue. So twenty-one exposures happened in a phantom mammographic using a CR equipment. Results were compared with data from the literature and was found an accuracy rate 15% lower than the recommended level. Experimental values reached below the IAEA’s acceptable levels for 3.0 to 6.0 cm thickness of the compressed breast.

Palavras Chave

mammography phantom; mean glandular dose; medical radiodiagnostic; metrology


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

José Ubiratan Delgado, José Guilherme Pereira Peixoto, Ricardo Tadeu Lopes

×

Simulação de um tubo de raios X clínico através do método de Monte Carlo usando código PENELOPE

Metrologia em raios X, raios gama, elétrons e partículas carregadas


Resumo

O câncer de mama é o tipo de neoplasia mais freqüente entre mulheres. A principal técnica de detecção precoce do câncer de mama é a mamografia. Apesar do avanço da diminuição das mortes por câncer, existe a preocupação dos danos causados pela radiação ionizante. O espectro é uma importante medida na caracterização do raios X. Para avaliar essa medida foi modelado um mamógrafo e obtidos os espectros em profundidade através do método de Monte Carlo usando o Código PENELOPE. Também foram calculadas as energias médias dos espectros em profundidade, a camada semi redutora do espectro de saída do mamógrafo.

Palavras Chave

mamografia; Monte Carlo; PENELOPE


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

Mariano Gazineu David, Carlos Eduardo de Almeida, delson braz, Luis Alexandre Gonçalves Magalhães, mario bernal

×

SPECTRA TRANSMITTED BY MORTAR BARITE IN X-RAY QUALITIES APPLIED IN DIAGNOSTIC RADIOLOGY AS SHIELDING

Metrologia nas áreas de saúde, indústria e proteção radiológica


Resumo

Concrete which contains water, cement and aggregate, is widely used in building construction such as medical hospitals. The CdZnTe spectrometry system was used to acquire the transmitted spectra in the RQR qualities and the stripping procedure was performed by taking into account both the contributions of efficiency and x-ray escape fraction, experimentally determined. The samples were prepared in rectangular plate format with dimensions of (5 x 5) cm with thicknesses varying from 0.2cm to 2cm and exposed to x-ray beams generated. The HVL and the mean energy in this energy range was determined.

Palavras Chave

shielding; barite mortar; x-ray spectra; concrete; ambient dose equivalent


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

Almeida Jr, A.T., Araújo, F. G. S., maria do socorro nogueira tavares, Santos, M. A. P.

×

TDCR and CIEMAT/NIST Liquid Scintillation Methods applied to the Radionuclide Metrology

Metrologia de radionuclídeos


Resumo

In this work are presented TDCR and CIEMAT/NIST methods of liquid scintillation implemented in National Institutes of Metrology for activity standardization of radionuclides which decay by beta emission and electron capture. The computer codes to calculate the detection efficiency take into account: decay schemes, beta decay theory, quenching parameter evaluation, Poisson statistic model and Monte Carlo simulation for photon and particle interactions in the detection system. Measurements were performed for 3H, 14C, 99Tc pure beta emitters in a large energy range, and 68Ge/68Ga which decay by electron capture and positron emission, with uncertainties smaller than 1% (k = 1).

Palavras Chave

Liquid scintillation; TDCR; CIEMAT/NIST; beta emitters; radionuclide standardization.


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

Carlos J. da Silva, Akira Iwahara, Jamir S. Loureiro, Antonio Eduardo de Oliveira, Luiz Tauhata, Ricardo Tadeu Lopes

×

The influence of different 192Ir sources geometries to the energy deposition

Metrologia em raios X, raios gama, elétrons e partículas carregadas


Resumo

In this paper, various simplifications of the HDR source Varian VariSource Classic model, in which 192Ir as a radionuclide is used, were compared. These simplifications were carried out by the simulation of Monte Carlo, using the MCNPX code. The different sources were compared through a distribution of energy deposition in a water phantom. Our results indicated that small simplifications will present no influence on the source response, and the removal of the entire capsule surrounding the radionuclide will present a difference of just 0.51% in the final response.

Palavras Chave

Brachytherapy; Monte Carlo Simulation; Dosimetry


Arquvo do Trabalho

Visualizar Arquivo


CoAutores

Paulo Eduardo Gonçalves, William S. Santos , Walmir Belinato, Linda V. E. Caldas, Ana Paula Perini

×